top of page
S1000 SAMPLE CUP

XRF SAMPLE CUPS

cp1000sc.jpg

Series 1000 Sample Cup

Double open-ended or single open-ended cells. The window films are fixed with extra wide thin-film sleeves designed to envelope and secure windows without trimming extraneous window film.

Single open-ended cells include external overflow reservoirs and puncturable seals for pressure equalisation between the sample cup and sample chamber.

S1500 SAMPLE CUP

XRF SAMPLE CUPS

cp1400sc.jpg

Series 1500 Sample Cup

Double open-ended cells with option to attach a microporous film to the back for pressure equalisation in applications using inert helium flushes or vacuum. The window films are fixed with snap on rings assuring leak-resistant seals. Alternatively, to a microporous film uniquely vented caps can be used (see Series 1600).

S1800 SAMPLE CUP

XRF SAMPLE CUPS

cp1800sc.jpg

Series 1800 Sample Cup

Single open-ended cells for the preparation of micro-samples or evaporated droplet samples. The provided collars and snap on rings allow “sandwiching” the sample in between two window films assuring leak-resistant seals. The cells include external overflow reservoirs and puncturable seals for equalising pressure differentials within the sample cup and sample.

S1935-OX SAMPLE CUP

XRF SAMPLE CUPS

cp1935oxsc.jpg

Series 1935-OX Sample Cup

Designed specifically as replacement cups and vented caps for Oxford analysers requiring the user supplied L240 aluminum sample holders with interior “O” ring seals (Oxford CK-100 Consumables Kit, P/N 54-CK-100).

S1300 SAMPLE CUP

XRF SAMPLE CUPS

cp1300sc.jpg

Series 1300 Sample Cup

Double open-ended cells with re-sealable caps to equalise pressure differentials between the sample cup and sample chamber. Caps include external overflow reservoirs. The window films are fixed with snap on rings assuring leak-resistant seals.

​

​

​

​

S1600 SAMPLE CUP

XRF SAMPLE CUPS

cp1600sc.jpg

Series 1600 Sample Cup

Slit-vented cell caps used in conjunction with Series 1500 sample cups to maintain equal pressures and avert distension or convolution of the thin-film window under positive or negative pressure conditions.

​

​

​

S1850 SAMPLE CUP

XRF SAMPLE CUPS

cp1850sc.jpg

Series 1850 Sample Cup

Single open-ended cells designed for instruments requiring an overall height shallower than conventional sample cups and a wide upper section. Cells include external overflow reservoirs and puncturable seals for equalising pressure differentials within the sample cup and sample chamber. The window films are fixed with snap on rings assuring leak-resistant seals.

S2100 SAMPLE CUP

XRF SAMPLE CUPS

cp2100sc.jpg

Series 2100 Sample Cup

Double open-ended cells which integrate an internal overflow reservoir for collecting thermally sensitive liquid samples within the sample cup and thus reducing the likelihood of inadvertent spillage into the sample chamber. The reservoirs also serve as reference point for filling cups with uniform sample volumes.

The snap on cap includes a vent hole for equalising pressure differentials within the sample cup and sample. The window films are fixed with extra wide thin film sleeves designed to envelope and secure windows without trimming extraneous window film.

S1400 SAMPLE CUP

XRF SAMPLE CUPS

cp1400sc.jpg

Series 1000 Sample Cup

Double open-ended or single open-ended cells. The window films are fixed with extra wide thin-film sleeves designed to envelope and secure windows without trimming extraneous window film.

Single open-ended cells include external overflow reservoirs and puncturable seals for pressure equalisation between the sample cup and sample chamber.

S1700 SAMPLE CUP

XRF SAMPLE CUPS

cp1700sc.jpg

Series 1700 Sample Cup

Single open-ended cells for the preparation of micro-samples or evaporated droplet samples. The provided collars and snap on rings allow “sandwiching” the sample in between two window films assuring leak-resistant seals. The cells include external overflow reservoirs and “Snap-Post” seals for equalising pressure differentials within the sample cup and sample. Jiggling the integrated “Snap-Post”, which is attached to the seal ruptures the seal.

S1900 SAMPLE CUP

XRF SAMPLE CUPS

cp1900sc.jpg

Series 1900 Sample Cup

Double open-ended cells for the preparation of micro-samples or evaporated droplet samples for analysis in helium flush or atmospheric conditions. The provided collars and snap on rings allow “sandwiching” the sample in between two window films assuring leak-resistant seals.

S3100 SAMPLE CUP

XRF SAMPLE CUPS

cp3100sc.jpg

Series 3100 Sample Cup

Double open-ended uniquely designed cells for the preparation of powdered, solid or liquid micro-samples (0.2 – 5.5 cc).

The funnel shaped cell interior consists of a larger conically shaped upper portion, which facilitates sample introduction, and a lower cylindrically shaped spout, which represents the actual sample chamber.

The snap on cap includes a vent hole for equalising pressure differentials within the sample cup and sample. The window films are fixed with a uniquely designed collar.

Cells fit into nominal 32 mm diameter sample holders.